- Free Download Prolink Version 1.15
- Sokkia Prolink 1.15 software, free download
- Sokkia Prolink Free Download
- Sokkia Prolink 1.15 software, free download
Prolink Software Corporation is committed to respecting and protecting your privacy. To that end, we have prepared this privacy statement to disclose and describe our information gathering and dissemination practices for this website.
Sokkia Prolink Download Software Download Wonder v.1.60 Download Wonder® works seamlessly with your browser to download files from the Internet, then manage and organize your downloads. ProLink Software. ProLink is used for: downloading data from any Sokkia device; editing of field data; reduction of raw data, RTK GPS and Total Station alike; import and export of various file formats as well as creation of your own conversions; management of coordinate system files (GPS).
- Sokkia GRX Utility 2.2 (sokkia.com.sg). Features of the GRX utility software includes: -Check or change GRX1 receiver settings -Upload firmware -Import data -Upload Option Authorization File (OAF) files -Configure GRX1 internal digital UHF radio and GSM settings including upload of channel frequencies -Detailed satellite information like Skyplots and DOP -And other analysis information of the.
- ProLink Software. ProLink was Download version 1.15 of ProLink To transfer a file from a Sokkia Total Station you can use the 'receive' function in ProLink. 4 696 users of Software Informer have this software installed on their The most commonly used version of Prolink is 1.15, with over 95% of all. ProLINK is a Shareware software in.
- Micro Motion ProLink III Configuration & Service Tool for Flow Meters Micro Motion Featuring an intuitive interface, the ProLink III Microsoft Windows-based software application empowers you to easily access all the information you may need to configure, assess and manage your Micro Motion and Rosemount flow meters.
Notice and Disclosure
In general, you may visit this website without identifying yourself or revealing any personal information. Prolink collects domain information from your visit to customize and improve your experience on our website. Some portions of this website may require you to give us personally identifiable information, which is information that enables us to identify you, such as your name, email or other address. If you opt to provide this information, we may also use it for purposes such as verifying your identity, sending you information, or contacting you.
Free Download Prolink Version 1.15
Cookies
Portions of this website may use cookies to keep track of your visit, or to deliver content specific to your interests. A cookie is a small amount of data transferred to your browser and read by the Web server that placed it there. It works as a sort of identification card, recording your preferences and previously entered information. You can set your browser to notify you when you receive a cookie, giving you the chance to accept or reject it.
Contact Us
If you have any questions or comments about our privacy statement or practices, please contact us via email at [email protected] with the words 'PRIVACY POLICY' in the subject line. Prolink Software reserves the right to modify or update this privacy statement at any time without notice.
Last updated February 13, 2018.
Last updated February 13, 2018.
ProLink Software
ProLink was last updated in July 2001. Its current freebee replacement is Spectrum Link, or for a maintained product go to the Magnet Office products.
The information below is for existing ProLink users, who may continue to use ProLink for its extensive export customisation functionality.
Known issues |
Downloading Total Station or SDR datalogger to the PC |
'I'm importing an ASCII file and ProLink crashes' |
Download version 1.15 of ProLink |
'XFM not found' (GPS) |
'Not an XFM project .. backed out' (GPS) |
Known or unknown Base coordinates - what's the go? (GPS) |
Interfacing with third party software - Landmark, Civilcad |
Sokkia Prolink 1.15 software, free download
Here are a few things to be aware of:
1. ProLink requires Administrator rights when using projects. Each project is stored in a directory of its own.
2. (GPS RTK only) Prolink does not use a geoid model, so be aware you may find height differences between the results from thet work
Terminal for mac os x 10.6.8. Download Terminal For Mac Os X 10.6.8 Ade Mac Os X 10 6 8 To 10 8 5 Download Terminal For Mac Os X 10.6.8 6 8 Update Oct 20, 2014 My Hard Drive went on my mac and after replacing it and reinstalling OS X 10.6.8 I cannot download Remote Desktop from the app store, it says I need at least OS X 10.7. I just downloaded python 2.7 on my mac which runs OS X 10.6.8. The previous version of python installed was 2.6. When I type python in the terminal it opens python version 2.6. I want it to open p. Jul 25, 2011Â About Mac OS X 10.6.8 Update. The 10.6.8 update is recommended for all users running Mac OS X Snow Leopard and includes general operating system fixes that enhance the stability, compatibility, and security of your Mac, including fixes that: Enhance the Mac App Store to get your Mac ready to upgrade to Mac OS X Lion.
5. (GPS RTK only). Reducing RTK data in Prolink: Antenna height of second and subsequent base stations in the same file are ignored - so if the second base station has a different antenna height, you'll see incorrect elevations for all points observed using that second base station. This only seems to happen on certain Operating Systems.
6. When re-opening a project, the co-ordinate order reverts to Northing, Easting, even if you set the default to Easting, Northing.
To transfer a file from a Sokkia Total Station you can use the 'receive' function in ProLink. After you have 'received' the file on the PC, you can 'import' it into a ProLink project.
For most Sokkia Total Stations use the SDR33 (SDR) device. You'll need to set the PC ready to receive and then 'send' the job from the Total Station.
If your Total Station or SDR check the following:
- are you connected to the correct com port? In case of doubt, try all COM ports.
- are the communication parameters the same on the PC and in the instrument? Check the speed (baud rate) but also the parity, data bits, stop bits. Leave Xon/Xoff unchecked and handshake 'none' for now.
- is the com port available? Not occupied by Activesync, for instance.
Older models like the SET2Cii and other C series with built-in Sokkia data cards will use the 'SCR2' device (set to 9600 baud regardless of RS232 speed in instrument !) to communicate. Set File Type in the left hand screen to *.SCR. These instruments should be set 'On Line' in the Menu/Card/Comms menu and will receive a *.scr (not SDR) file to the PC.
The same settings apply if you're using an external SCR2 card reader.
The same settings apply if you're using an external SCR2 card reader.
If you have (intermittent) communication problems between the SDR33 and the Total Station, the cable attached to the SDR33 is likely to be faulty. Once you have a new cable, make sure not to squash the cable by inserting the SDR33 head first into the carry pouch.
' I'm importing an ASCII file and ProLink crashes '
Have a look (with e.g. Notepad, not MSWord) at thell get an error message if following files are recorded on other zones or did not use an .xfm file. Jillian michaels 30 day shred level 2 avi video download.
Have a look (with e.g. Notepad, not MSWord) at thell get an error message if following files are recorded on other zones or did not use an .xfm file. Jillian michaels 30 day shred level 2 avi video download.
1. If you do not have known coordinates for the GPS base station, use 'unknown' setting. You can now enter completely arbitrary coordinates. But you must visit a known point with the rover and perform a calibration on the setting - and you don't need to do a calibration. But visit a known point as a check.
'Known' implies that the initial coordinate system will be using the entered known northing and easting as starting point.
'Unknown' implies that the initial coordinate system will use the autonomous GPS coordinates, converted to northing and easting. This should get your job within a few meters.
'Unknown' implies that the initial coordinate system will use the autonomous GPS coordinates, converted to northing and easting. This should get your job within a few meters.
Sokkia Prolink Free Download
Similarly to the xfm setting of the first file, it is the setting in the first file which determines whether 'known' or 'unknown' initial coordinates are used in a ProLink project.
Sokkia Prolink 1.15 software, free download
3. In case you entered known coordinates for your base station, but left the Base Coord field 'unknown' by accident , and you did not do a calibration, you will find all of your coordinates off by the same amount. To correct this situation, change 'arbitrary' to 'known' in ProLink's field book view, export the field book file as SDR file and import this new file into a NEW project. Or import another file with 'known' setting first ..